Sanitary Constant Pressure Valves – Adamant Valves https://www.adamantvalves.com Sanitary Valves And Fittings, Sanitary Pumps Thu, 12 Jan 2023 07:36:26 +0000 en-US hourly 1 https://wordpress.org/?v=4.9.18 https://www.adamantvalves.com/wp-content/uploads/2016/01/cropped-Valves-Logo-1-32x32.jpg Sanitary Constant Pressure Valves – Adamant Valves https://www.adamantvalves.com 32 32 AV-9T Sanitary Tri-Clamp Constant Pressure Valve with Superchanger https://www.adamantvalves.com/av-9t-sanitary-tri-clamp-constant-pressure-valve-with-superchanger.html https://www.adamantvalves.com/av-9t-sanitary-tri-clamp-constant-pressure-valve-with-superchanger.html#respond Fri, 23 Jul 2021 03:23:39 +0000 https://www.adamantvalves.com/?post_type=product&p=10599 Working temperature -10 to 150 °C Working pressure 8 bar Body material 304/316L Sealing material EPDM + PTFE (FDA177.2600) Connection Clamp, thread, welding Finishing Ra< 0.6µm Standards ISO, DIN, SMS, RJT

The post AV-9T Sanitary Tri-Clamp Constant Pressure Valve with Superchanger appeared first on Adamant Valves.

]]>
Sanitary Tri-Clamp Constant Pressure Valve with Supercharger Description

The Sanitary Tri-Clamp Constant Pressure Valve with Supercharger is operated by compressed air, which automatically runs without a sensor on the piping system or other auxiliary instruments, and only one compressed air pressure regulating valve that maintains pressure stability can work normally.

  • Constant Pressure Valve-V Type:

Constant inlet pressure.

The valves open when the pressure of the conveying medium is higher than the set pressure.

When the pressure of the conveying medium decreases, the valve changes the flow accordingly.

The valves are closed when the conveying medium is insufficient.

  • Constant Pressure Valve-A Type:

Constant outlet pressure.

The valves are closed when the pressure of the conveying medium is higher than the set pressure.

When the pressure of the conveying medium decreases, the valve changes the flow accordingly.

The valves open when the conveying medium is insufficient.

Sanitary Tri-Clamp Constant Pressure Valve

Sanitary Tri-Clamp Constant Pressure Valve With Supercharger Specifications

Size Custom
Working temperature -10 to 150 °C
Working pressure 8 bar
Max working pressure 12 bar Supercharger (option)
Body material 304/316L
Sealing material EPDM + PTFE (FDA177.2600)
Connection Clamp, thread, welding
Finishing Ra< 0.6µm
Standards ISO, DIN, SMS, RJT

pressure valve

Size D D1 A B L1 L2 H1 H2
V Type 1.5″ 38.1 50.5 1.5 206 130 62 215 18
2″ 50.8 64 1.5 206 130 69 215 18
2.5″ 63.5 77.5 2 206 130 69 215 18
A Type 1.5″ 38.1 50.5 1.5 206 130 78 230 18
2″ 50.8 64 1.5 206 130 85 230 18
2.5″ 63.5 77.5 2 206 130 85 230 18

constant pressure valve

Sanitary Tri-Clamp Constant Pressure Valve With Supercharger Options

  • Connections: Butt-weld, sanitary clamp, flange, thread, etc. (DIN, IDF, SMS, RJT, 3A standard)
  • Seals and gaskets: EPDM as default, Silicone, or Viton (FPM) are available upon request.
  • Pressure range adjustable (by calibrating spring).

superchanger

With supercharger

Sanitary Tri-Clamp Constant Pressure Valve With Supercharger Applications

  • The safety valve is used to protect pipelines and pumps from overpressure
  • Pressure relief design prevents operation danger and equipment brake down
  • With a pure stainless-steel design, the valve is the best choice for protecting equipment in the dairy, food, beverage, pharmaceutical, and fine chemical industries.

Related products: AV-9M SANITARY MINI SAFETY VALVE WITH TRI-CLAMP, AV-9ST SANITARY HIGH PURITY S-TYPE PRESSURE REDUCING VALVE, AV-9P SANITARY HIGH PURITY L-TYPE PRESSURE REDUCING VALVE WITH TRI-CLAMP ENDS, MANUAL TYPE, AV-9B SANITARY PRESSURE RELIEF BUNGING VALVE WITH TRI-CLAMP ENDS, MANUAL TYPE, AV-9VB SANITARY VACUUM BREAKER, AV-9PV SANITARY PRESSURE VACUUM RELIEF VALVES

The post AV-9T Sanitary Tri-Clamp Constant Pressure Valve with Superchanger appeared first on Adamant Valves.

]]>
https://www.adamantvalves.com/av-9t-sanitary-tri-clamp-constant-pressure-valve-with-superchanger.html/feed 0
AV-8P Sanitary Plate Heat Exchanger https://www.adamantvalves.com/av-8p-sanitary-plate-heat-exchanger.html https://www.adamantvalves.com/av-8p-sanitary-plate-heat-exchanger.html#respond Mon, 30 Nov 2020 08:59:32 +0000 https://www.adamantvalves.com/?post_type=product&p=9034 Specifications:

Plate Material: 304 or 316L
Body Material: 304
Gasket Material: NBR, EPDM, etc
Max Working Pressure: 3Mpa
Working temperature: -10℃ - +150℃
Cooling: Single stage or two stages
Size: 1m², 3m², 5m², 7m², 10m²
Plate Material: 304 or 316L

The post AV-8P Sanitary Plate Heat Exchanger appeared first on Adamant Valves.

]]>
Sanitary Plate Heat Exchanger Description:

Modular design makes Sanitary Plate Heat Exchangers easy to adapt to new or changing process requirements. Different plate types, plate materials, plate lengths, gasket materials, and options make it an adaptable choice for a wide range of hygienic processes.

Sanitary Plate Heat Exchanger Specifications:

Plate Material: 304 or 316L
Body Material: 304
Gasket Material: NBR, EPDM, etc
Max Working Pressure: 3Mpa
Working temperature: -10℃ – +150℃
Cooling: Single stage or two stages
Size: 1m², 3m², 5m², 7m², 10m²
Plate Material: 304 or 316L

Sanitary Plate Heat Exchanger

Model Number Plate Size

(length*width*height)

Channel Heat Exchange Area

(M²)

Flow

(T/H)

1 160*500*0.5 Single Channel 1 0.5
1 160*500*0.5 Double Channel 3 1.5
2 200*800*0.4 Double Channel 5 2.5
2 200*800*0.4 Double Channel 7 3
2 200*800*0.4 Double Channel 10 5

Sanitary Plate Heat Exchanger Applications:

Pasteurization

Normal cooling and heating in such industries as dairy, brewage, beverage, food, etc.

Heating and cooling in pharmaceutical industry.

 

The post AV-8P Sanitary Plate Heat Exchanger appeared first on Adamant Valves.

]]>
https://www.adamantvalves.com/av-8p-sanitary-plate-heat-exchanger.html/feed 0
AV-8M Mini-Type Constant Pressure Valve https://www.adamantvalves.com/mini-type-constant-pressure-valve.html https://www.adamantvalves.com/mini-type-constant-pressure-valve.html#respond Wed, 13 May 2020 07:22:04 +0000 https://www.adamantvalves.com/?post_type=product&p=8888 Specifications:

Size 3/4"-1.25",DN20-DN32
KV value 10-21m³/h
Working temperature -10 to 150 °C
Working pressure 8 bar
Max working pressure 12 bar (option)
Body material 316L/304
Sealing material EPDM+PTFE(FDA177.2600)
Connection Clamp, thread, weld
Finishing Inside Ra≤0.6 μm
Standards ISO, DIN, SMS, RJT

The post AV-8M Mini-Type Constant Pressure Valve appeared first on Adamant Valves.

]]>
Mini-Type Constant Pressure Valve Description

Mini-Type Constant Pressure Valve can ensure stable pressure at both outlet and inlet. The Mini-Type Constant Pressure Valve is widely used in separators, heat exchangers, tank systems, and other equipment. It also can be used as a relief valve.

mini type constant pressure valve

Mini-Type Constant Pressure Valve Specifications

Size 3/4″-1.25″,DN20-DN32
KV value 10-21m³/h
Working temperature -10 to 150 °C
Working pressure 8 bar
Max working pressure 12 bar (option)
Body material 316L/304
Sealing material EPDM+PTFE(FDA177.2600)
Connection Clamp, thread, weld
Finishing Inside Ra≤0.6 μm
Standards ISO, DIN, SMS, RJT

Mini-Type Constant Pressure Valve-2

 

Size D D1 A B L1 L2 H1 H2
1″ 25.4 50.5 1.5 118 70 58 162 16
1″ 25.4 50.5 1.5 118 70 58 172 16

Mini-Type Constant Pressure Valve-3

Mini-Type Constant Pressure Valve Applications:

The Mini-Type Constant Pressure Valve is widely used in the rear of separators, heat exchangers, canned systems, etc., and as an overflow valve because it can ensure a stable pressure at the valve outlet and inlet.

The post AV-8M Mini-Type Constant Pressure Valve appeared first on Adamant Valves.

]]>
https://www.adamantvalves.com/mini-type-constant-pressure-valve.html/feed 0
AV-8 Sanitary Constant Pressure Valves https://www.adamantvalves.com/av-8-sanitary-constant-pressure-valves.html https://www.adamantvalves.com/av-8-sanitary-constant-pressure-valves.html#respond Tue, 10 Sep 2019 06:18:10 +0000 http://www.tungstenhome.com/product/av-8-sanitary-constant-pressure-valves Working temperature -10 to 150 °C Working pressure 8 bar Body material 304/316L Sealing material EPDM + PTFE (FDA177.2600) Connection Clamp, thread, welding Finishing Ra< 0.6µm Standards ISO, DIN, SMS, RJT

The post AV-8 Sanitary Constant Pressure Valves appeared first on Adamant Valves.

]]>
Sanitary Constant Pressure Valves Description

The Sanitary Tri-Clamp Constant Pressure Valve with Supercharger is operated by compressed air, which automatically runs without a sensor on the piping system or other auxiliary instruments, and only one compressed air pressure regulating valve that maintains pressure stability can work normally.

  • Constant Pressure Valve-V Type:

Constant inlet pressure.

The valves open when the pressure of the conveying medium is higher than the set pressure.

When the pressure of the conveying medium decreases, the valve changes the flow accordingly.

The valves are closed when the conveying medium is insufficient.

  • Constant Pressure Valve-A Type:

Constant outlet pressure.

The valves are closed when the pressure of the conveying medium is higher than the set pressure.

When the pressure of the conveying medium decreases, the valve changes the flow accordingly.

The valves open when the conveying medium is insufficient.

Sanitary Constant Pressure Valves Specifications

Size Custom
Working temperature -10 to 150 °C
Working pressure 8 bar
Body material 304/316L
Sealing material EPDM + PTFE (FDA177.2600)
Connection Clamp, thread, welding
Finishing Ra< 0.6µm
Standards ISO, DIN, SMS, RJT

constant pressure valves

Size D D1 A B L1 L2 H1 H2
V Type DN40 40 50.5 1.5 206 130 62 215 18
1.5” 38.1
DN50 52 64 1.5 206 130 69 215 18
2” 50.8
2.5” 63.5 77.5 2 206 130 69 215 18
A Type DN40 40 50.5 1.5 206 130 78 230 18
1.5” 38.1
DN50 52 64 1.5 206 130 85 230 18
2” 50.8
2.5” 63.5 77.5 2 206 130 85 230 18

pressure valves

Sanitary Constant Pressure Valves Applications

AV-8 series constant pressure valve can ensure a stable pressure at both outlet and inlet. It is widely used in separators, heat exchangers, tank systems, and other equipment. It also can be used as a relief valve.

Related products: AV-9M SANITARY MINI SAFETY VALVE WITH TRI-CLAMP, AV-9ST SANITARY HIGH PURITY S-TYPE PRESSURE REDUCING VALVE, AV-9P SANITARY HIGH PURITY L-TYPE PRESSURE REDUCING VALVE WITH TRI-CLAMP ENDS, MANUAL TYPE, AV-9B SANITARY PRESSURE RELIEF BUNGING VALVE WITH TRI-CLAMP ENDS, MANUAL TYPE, AV-9VB SANITARY VACUUM BREAKER, AV-9PV SANITARY PRESSURE VACUUM RELIEF VALVES

The post AV-8 Sanitary Constant Pressure Valves appeared first on Adamant Valves.

]]>
https://www.adamantvalves.com/av-8-sanitary-constant-pressure-valves.html/feed 0